Pressurized Thermosiphon Solar Energy System
To the atmosphere
Fully Closed
New generation
Solar energy
System...
Systems in which the heating fluid or the fluid to be heated automatically circulates between the collector and the tank, without an additional pump or any similar movement mechanism, are called natural circulation systems.
Natural Circulation systems perform circulation according to the density difference between heating and cooling of the heating fluid or the fluid to be heated.
In natural circulation systems, the heating fluid circulates between the tank and the collector 8-10 times a day.
An advantage of pressurized systems over float systems is that they have the same or higher pressure as cold water at the place of use. In this way, the risk of scalding with very hot water in the bathroom is less. In float systems, the hot water pressure is only as much as the static pressure caused by the elevation (floor height) difference between the tank level and the place of use. This causes the cold water to be shifted upwards to the hot water in the armatures (due to the difference in the mains pressures of the cold and hot water) and an unbalanced temperature water flow.
THERMO MATE SCL SERIES
Thermosiphon Solar Energy System
SCL 120 / 170 / 200 / 300 / 500
(Closed Circuit Systems with Heating Fluid (Antifreeze))
There is a heat exchanger jacket-exchanger around the hot water tank in TERMOMATE Heating Fluid Closed circuit systems. The heating fluid (antifreeze) moves between the collector and the heat exchanger jacket-exchanger and transmits the heat generated in the collector to the domestic water in the tank. Closed Circuit Thermosiphon Systems do not need an external expansion tank. An optional electrical backup ensures energy continuity even in cloudy weather.
SOL 120 / SCL 120 - SOL 150 / SCL 150
THERMO MATE SERIES
Thermosiphon Solar Energy System
SOL 170 / SCL 170 - SOL 200 / SC 200
THERMO MATE SERIES
Thermosiphon Solar Energy System
THERMO MATE LEFT SERIES
Thermosiphon Solar Energy System
LEFT 120 / 170 / 200 / 300 /500
(Open Circuit Systems Without Heating Fluid (Without Antifreeze))
TERMOMATE Open Circuit Systems without Heating Fluid are both simple and economical compared to Closed Circuit Systems. It is a model developed for climates where water quality is suitable and there is no risk of freezing. It does not need heating fluid and heat exchanger, the domestic water in the tank is heated by going to the collector. The heated water returns to the tank and thus domestic hot water is obtained.
are systems.
SOL 300 / SCL 300 - SOL 500 / SC 500
THERMO MATE SERIES
Thermosiphon Solar Energy System